Weintek Love in the Wild
10 Bar Smoke Tube Dual Fuel Boiler Panel Retrofit
Hardware:
Controller: SIEMENS S7-1214C AC/DC/Rly
Monitoring: Weintek HMI MT8102iP
Software:
TIA Portal V18
10 Bar Smoke Tube Dual Fuel Boiler Panel Retrofit
Hardware:
Controller: SIEMENS S7-1214C AC/DC/Rly
Monitoring: Weintek HMI MT8102iP
Software:
TIA Portal V18
I've been using them for quite some time. The graphics are pretty good. The drivers are the big plus. Modbus is straight forward for CoDeSys (Wago & stuff). They also offer their own CoDeSys I/O and such (you need to pick the right unit for it though). I even used them for some old SLC replacements serial & Ethernet, beats PV!! And yes, Maple has a great support team if you need it. Weintek as well as Maple have their own YouTube channels. You'll find pretty much everything on there as far as setting up a unit.
I've been using them for quite some time. The graphics are pretty good. The drivers are the big plus. Modbus is straight forward for CoDeSys (Wago & stuff). They also offer their own CoDeSys I/O and such (you need to pick the right unit for it though). I even used them for some old SLC replacements serial & Ethernet, beats PV!! And yes, Maple has a great support team if you need it. Weintek as well as Maple have their own YouTube channels. You'll find pretty much everything on there as far as setting up a unit.
I have used their advanced series HMI which has a Codesys runtime on it before. It worked just fine, though the customer required LD and I am not a fan of the Codesys LD editor. I have also used a ton of their iR series remote I/O racks. They are one of my go-to solutions when I need to add I/O to a Modbus or EIP PLC.
I have used their advanced series HMI which has a Codesys runtime on it before. It worked just fine, though the customer required LD and I am not a fan of the Codesys LD editor. I have also used a ton of their iR series remote I/O racks. They are one of my go-to solutions when I need to add I/O to a Modbus or EIP PLC.
Nice to see on Linkedin solutions by our partners around the world. Like the one of Lamonde Automation Limited
#Teknokol enclosure, support arm and kiosk system, we're showcasing products from Weintek (cMT2078X+CODESYS & iR-ETN40P I/O module),
#Teltonika Networks (RUT241 router and TSW010 5 port unmanaged switch) and EMAS Electric UK (BRJ45 for external Ethernet connections).
#iot
#wirelesscommunications
Nice to see on Linkedin solutions by our partners around the world. Like the one of Lamonde Automation Limited
#Teknokol enclosure, support arm and kiosk system, we're showcasing products from Weintek (cMT2078X+CODESYS & iR-ETN40P I/O module),
#Teltonika Networks (RUT241 router and TSW010 5 port unmanaged switch) and EMAS Electric UK (BRJ45 for external Ethernet connections).
#iot
#wirelesscommunications
What would you do if you needed to measure high frequency inputs in a PLC-based application?
In my experience, I always prefer to relieve the PLC of this burden and utilize a separate module for high-frequency measurements. For example, I recently investigated the capabilities of the new Weintek iR-PU01-P module, which can receive pulse input at up to 2MHz, and the findings were extremely positive. Despite the fact that the PU01-P is a 1-axis module designed for motion control, it has proven to be an extremely useful solution for measuring simple high frequency pulses from our TCS product flow meters in our fuel additive injection calibration loop, improving performance, reducing PLC load, and increasing accuracy and scalability.
What would you do if you needed to measure high frequency inputs in a PLC-based application?
In my experience, I always prefer to relieve the PLC of this burden and utilize a separate module for high-frequency measurements. For example, I recently investigated the capabilities of the new Weintek iR-PU01-P module, which can receive pulse input at up to 2MHz, and the findings were extremely positive. Despite the fact that the PU01-P is a 1-axis module designed for motion control, it has proven to be an extremely useful solution for measuring simple high frequency pulses from our TCS product flow meters in our fuel additive injection calibration loop, improving performance, reducing PLC load, and increasing accuracy and scalability.
I have used Weintek for at least 10 years now. Hundreds of HMI deployments over many industries and in some harsh conditions. Recently I’ve been doing some building automation stuff using the more advanced versions of the HMIs with Codesys. and the iR IO modules.
Also, lately I’ve been working at things like remote connections with the headless SVRX HMIs and EasyAccess2.0.
I really enjoy using the Weintek equipment and hope to have many more opportunities with it.
I have used Weintek for at least 10 years now. Hundreds of HMI deployments over many industries and in some harsh conditions. Recently I’ve been doing some building automation stuff using the more advanced versions of the HMIs with Codesys. and the iR IO modules.
Also, lately I’ve been working at things like remote connections with the headless SVRX HMIs and EasyAccess2.0.
I really enjoy using the Weintek equipment and hope to have many more opportunities with it.
